Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. colomb. anestesiol ; 48(3): 111-117, July-Sept. 2020. tab, graf
Article in English | LILACS, COLNAL | ID: biblio-1126292

ABSTRACT

Abstract Introduction: Total intravenous anesthesia (TIVA) and balanced anesthesia (BA) are the most commonly used anesthetic techniques. The differences are the variability of the depth of anesthesia between these techniques that might predict which one is safer for patients and presents a lower risk of intraoperative awakening. Objective: To determine whether a difference exists in the variability of depth of anesthesia obtained by response entropy (RE). Methods: A crossover clinical trial was conducted on 20 healthy patients receiving upper or lower limb ambulatory orthopedic surgery. Patients were randomly assigned to (a) target-controlled infusion of propofol using the Schnider model at a target concentration of 2.5 µg/mL for 15 minutes and a 10-minute washout, followed by sevoflurane administration at 0.8 minimal alveolar concentration (MAC) for the reminder of the surgery, or (b) the reverse sequence. Differences in the variability of the depth of anesthesia using RE were evaluated using paired t-test. Results: The treatment effect showed no significant difference in the average values of RE, during TIVA = 97.23 vs BA 97.04 (P = 0.39). Carry Over (-4.98 vs 4.08) and Period (100.3 vs 94.68) effects were not significantly different. Conclusion: The present study suggests that both anesthetic techniques are equivalent in terms of the stability of the depth of anesthesia. It is important to keep testing the determinants of the efficacy of different populations because the individual behaviors of patients might ultimately tip the scale.


Resumen Introducción: La anestesia total intravenosa (TIVA, por sus siglas en inglés) y la anestesia balanceada (AB) son las técnicas anestésicas más comúnmente utilizadas. La diferencia está en la variabilidad de la profundidad de la anestesia entre estas dos técnicas, lo cual pudiera predecir cuál es más segura para los pacientes y representar un menor riesgo de despertar intraoperatorio. Objetivo: Determinar si existe alguna diferencia en la variabilidad de la profundidad de la anestesia obtenida según los índices de entropía de respuesta (ER). Métodos: Se llevó a cabo un estudio clínico cruzado en 20 pacientes sanos que se sometieron a cirugía ortopédica ambulatoria de miembros superiores o inferiores. Los pacientes se asignaron aleatoriamente así: a) infusión controlada por objetivo (TCI, por sus siglas en inglés) de propofol, utilizando el modelo Schnider a una concentración objetivo de 2,5 µg/mL durante 15 min y un período de lavado de 10 minutos, seguido de la administración de sevoflurano a 0,8 de concentración alveolar mínima (CAM) durante el tiempo restante de la cirugía; o b) la secuencia inversa. Las diferencias en la variabilidad de la profundidad de la anestesia utilizando entropía de respuesta se evaluaron utilizando la prueba t pareada. Resultados: El efecto del tratamiento no mostró ninguna diferencia significativa en los valores promedio de entropía de respuesta (ER) durante TIVA = 97,23 vs. AB 97,04 (P = 0,39). Los efectos de arrastre (-4,98 vs. 4,08) y período (100,3 vs. 94,68) no fueron significativamente diferentes. Conclusiones: El presente estudio sugiere que ambas técnicas anestésicas son equivalentes en términos de estabilidad de la profundidad de la anestesia. Es importante continuar probando los factores determinantes de eficacia en las distintas poblaciones, ya que el comportamiento individual de cada paciente pudiera finalmente inclinar la balanza.


Subject(s)
Humans , Male , Female , Adult , Entropy , Intraoperative Awareness , Balanced Anesthesia , Anesthesia, Intravenous , Propofol , Epidemiologic Methods , Sevoflurane
2.
Rev. cuba. inform. méd ; 11(1)ene.-jun. 2019. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1093305

ABSTRACT

La anestesia general proporciona al paciente estados de inconciencia, amnesia y analgesia, sin embargo, se reportan casos de despertar intraoperatorio. Debido a la incidencia de este fenómeno y sus efectos psicosomáticos, el Centro de Estudios de Neurociencias, Procesamiento de Imágenes y Señales en la Universidad de Oriente, y el Hospital General Juan Bruno Zayas Alfonso ambos en Santiago de Cuba, Cuba, implementan una metodología que permita detectar automáticamente estados de sedación anestésica aplicando Inteligencia Artificial. Para esto se emplearon las señales registradas por el canal electroencefalográfico F4, nueve parámetros espectrales, las Máquinas de Soporte Vectorial y los Sistemas Neuro-Difusos. En el reconocimiento automático de los estados de Sedación Profunda, Moderada y Ligera se logró una Exactitud de 96.12 por ciento, 90.06 por ciento y 90.24 por ciento respectivamente con las Máquinas de Soporte Vectorial, por lo que se propone el uso del canal electroencefalográfico F4 en la detección de estados anestésicos(AU)


General anesthesia provide the patient states of unconsciousness, amnesia and analgesia, however, cases of intraoperative awareness are reported. Due to the incidence of this phenomenon and the psychosomatic effects it causes, the Neuroscience Studies Center, Images and Signals Processing at the University of Oriente, and the General Hospital Juan Bruno Zayas Alfonso both in Santiago de Cuba, Cuba, implement a methodology that allows the automatic detection of anesthetic sedation states applying Artificial Intelligence. For this, the signals recorded by the electroencephalographic channel F4, nine spectral parameters, the Support Vector Machines and the Neuro-Fuzzy Systems were used. In the automatic recognition of the Sedation States: Profound, Moderate and Mild an Accuracy of 96.12 percent, 90.06 percent and 90.24 percent respectively was achieved with the Support Vector Machines, so the use of the electroencephalographic channel F4 is proposed in the detection of anesthetic states(AU)


Subject(s)
Humans , Male , Female , Cerebrovascular Disorders/diagnostic imaging , Electroencephalography/methods , Deep Sedation , Intraoperative Awareness
SELECTION OF CITATIONS
SEARCH DETAIL